Updated 16 November 2026: first published; the factor list as the free lookup showed it on this date.
Every emissions figure is activity data times a factor. The activity data is yours: kWh, tonnes of coal, litres of diesel. The factor comes from someone else, and your report is only as good as your choice of factor and your citation of it.
The free Indian emission factor lookup lists the factors CarbonNeeti applies for a fiscal year and an industry, each with its source, edition, year, unit and licence. No sign-up, and nothing you type is saved to an account or our database. This guide explains where each group comes from.
Grid electricity: CEA
The Central Electricity Authority publishes the CO2 Baseline Database for the Indian Power Sector each year. Scope 2 uses its all-India weighted average, including imports, for the fiscal year. Version 22.0 gives:
| Fiscal year | tCO2/MWh |
|---|---|
| FY 2019-20 | 0.709 |
| FY 2020-21 | 0.698 |
| FY 2021-22 | 0.711 |
| FY 2022-23 | 0.716 |
| FY 2023-24 | 0.727 |
| FY 2024-25 | 0.710 |
| FY 2025-26 | 0.675 |
BRSR and GHG inventories use the reporting year's factor. CCTS uses the FY 2023-24 baseline-year factor, 0.727, in every compliance year (BEE Detailed Procedure v1.0, s.5(7)(vi)). If CEA has not published a year yet, the lookup shows the latest earlier year and says so. Our guide to CEA grid emission factors covers how CEA builds the number.
Fuels: IPCC 2006, with Indian calorific values
A fuel's CO2 factor per unit is its net calorific value (NCV) x its carbon factor per unit of energy x the oxidation factor. The carbon factors are IPCC 2006 defaults (Volume 2, Table 2.2) and the oxidation factor is 1.0 at Tier 1. The NCV is the IPCC default (Volume 2, Table 1.2) for most fuels. Indian non-coking coal uses 19.6 GJ per tonne from India's National Communication (NATCOM), an Indian figure rather than the IPCC default.
Litres and kilolitres become tonnes at the densities PPAC publishes in its Snapshot of India's Oil and Gas data. The Scope 1 fuel method works through each step.
Each fuel shows two values. The first is CO2 only, the basis CCTS uses. The second adds CH4 and N2O at the IPCC stationary combustion category for the plant's industry, as BRSR and the GHG inventory count them.
Process and fugitive factors
These are per unit of product or of gas released. Clinker calcination, for example, is 0.52 tCO2 per tonne of clinker at the IPCC 2006 Volume 3 Tier 1 default. A few process factors are set per industry, so the industry you choose can change them.
Some have no published source. The pulp and paper chemical recovery factor (0.28 tCO2e per tonne of paper) and the refinery process factor (0.04 tCO2e per tonne of crude processed) are labelled "Industry estimate" in the lookup, not given a publisher. Use your plant's own measurements in their place where you can. Our emission factors reference lists the process factors by sector.
Scope 3 factors
These are physical factors, per kg, per km, per tonne-km and the like, by GHG Protocol category. Spend-based factors are not used. The sources are:
- India GHG Program, 2015, version 1.0, for Indian transport such as auto rickshaws and cars by engine size
- UK DEFRA GHG conversion factors, 2024 v1.1, for well-to-tank fuel factors among others
- US EPA GHG Emission Factors Hub, 2023
- CEA CO2 Baseline Database, v22.0, for a transmission and distribution loss factor derived from the grid factor
Worked example: what "diesel" returns
Search the lookup for "diesel" in FY 2025-26 and it finds 25 rows. A few of them:
| Factor | CO2 only | With CH4 and N2O | Source |
|---|---|---|---|
| Diesel, per tonne | 3.1863 | 3.1968264 | IPCC 2006 |
| Diesel, road vehicles, per tonne | 3.1863 | 3.23661 | IPCC 2006 |
| Diesel, off-road machinery, per tonne | 3.1863 | 3.52685355 | IPCC 2006 |
| Well-to-tank diesel, kgCO2e per litre | 0.62409 | UK DEFRA 2024 v1.1 | |
| Auto rickshaw, diesel, kgCO2e per km | 0.1322 | India GHG Program 2015 |
The CO2 per tonne of diesel is the same wherever it burns: 43.0 GJ x 74.1 kg/GJ = 3.1863 tCO2. The CH4 and N2O depend on the engine, which is why a generator, a truck and an excavator each get their own all-gas value. The last two rows are Scope 3: the emissions of producing and moving the fuel, and of an employee's commute.
How to cite a factor
Give the publication, its edition, the fiscal year and the value with its unit. For example: "CEA CO2 Baseline Database, Version 22.0, FY 2025-26, 0.675 tCO2/MWh" or "2006 IPCC Guidelines, Volume 2, Table 2.2, 74.1 kg CO2/GJ". Your Verifier checks the figure against that source, so a citation that names only "CEA" or "IPCC" sends them looking.
What the lookup leaves out
- Your own test data. A lab NCV for your coal, or a gas bill's stated calorific value, beats any default.
- Licence terms beyond the record. Each row shows the licence CarbonNeeti records. IPCC defaults are cited numbers, with no IPCC text copied. Where a row says the licence is not recorded, check the publisher's terms before you reuse it.
- Supplier-specific factors. A market-based Scope 2 figure or a supplier's own product footprint replaces a default only with evidence behind it.
Where CarbonNeeti fits
CarbonNeeti applies the right factor to every reading for the right year and shows the source on every figure in your report. To apply the factors now, use the Scope 2 electricity calculator or the Scope 1 fuel calculator.