CarbonNeeti

Free Tools · Emissions · Emission Factors · Technical

Scope 2 Electricity Emissions in India: The Method, Step by Step

Turn the kWh on your electricity bills into Scope 2 emissions at the CEA grid factor for the year, with a worked example and what the figure leaves out.

By the CarbonNeeti teamPublished 6 min read

Share

Updated 16 November 2026: first published; every figure checked against CEA CO2 Baseline Database Version 22.0, the edition the free calculator uses.

Scope 2 covers the emissions from the electricity, heat and steam you buy. For grid electricity in India, the figure that matters is CO2. Your plant burns nothing to cause it; a power station somewhere on the grid does. In India the figure rests on one number from the Central Electricity Authority (CEA): the all-India grid emission factor for the fiscal year.

You can do the arithmetic below by hand, or use the free Scope 2 electricity calculator. Enter the kWh from your bills and the fiscal year. It shows the factor and its source under the result. No sign-up, and nothing you type is saved to an account or our database.

Who needs the figure

  • Listed companies filing a BRSR. Principle 6 asks for Scope 1 and Scope 2 emissions and their intensity. Our guide to BRSR Principle 6 shows where each number goes.
  • Plants with a CCTS target. Purchased electricity counts in the plant's GHG emission intensity, but at a fixed factor (see below).
  • Any company preparing a GHG Protocol inventory, or answering a customer's supplier questionnaire.

The method

  1. Add up the kWh on the year's bills, grid and open access together.
  2. Divide by 1,000 to get MWh.
  3. Multiply by CEA's all-India weighted average grid factor for that fiscal year, in tCO2 per MWh. That is location-based Scope 2.

CEA publishes the factor in its CO2 Baseline Database for the Indian Power Sector. Version 22.0, dated 1 August 2026, gives these weighted averages:

Fiscal yearGrid factor (tCO2/MWh)
FY 2021-220.711
FY 2022-230.716
FY 2023-240.727
FY 2024-250.710
FY 2025-260.675

Use the factor for the year the electricity was used. If CEA has not published that year yet, as for FY 2026-27 today, the calculator uses the latest earlier year and says so. Replace it with the year's own factor once CEA publishes it.

The factor covers CO2 only, so this is a CO2-only estimate of your grid electricity, in tCO2. If you report it as tCO2e, say that it counts CO2 only. Purchased heat and steam are Scope 2 as well, each at its supplier's factor.

Worked example: 12,00,000 kWh in FY 2025-26

A manufacturing plant's bills for FY 2025-26 add up to 12,00,000 kWh. Of that, 3,00,000 kWh came from a solar developer through open access.

  • 12,00,000 kWh / 1,000 = 1,200 MWh
  • 1,200 MWh x 0.675 tCO2/MWh = 810.00 tCO2, location-based

This is what the calculator returns for those inputs. It is also the figure CarbonNeeti stores for the same reading: the same factor table, the same unit conversion and the same rounding (half up, to six decimals).

The 3,00,000 renewable kWh do not lower the location-based figure. Location-based counts every kWh at the grid average.

A second figure, market-based, can give the renewable power its own factor. The calculator shows one only when you name the instrument behind the power (a PPA or open access contract, a green tariff, a CERC REC or an I-REC) say the power is solar, wind or hydro, and confirm it meets the GHG Protocol Scope 2 Quality Criteria. If this plant's open access contract for solar power qualifies:

  • 12,00,000 - 3,00,000 = 9,00,000 kWh stay at the grid factor
  • 9,00,000 x 0.675 / 1,000 = 607.50 tCO2, market-based

The renewable kWh count at zero. The rest is at the grid factor as an approximation: India publishes no residual mix, and if your supplier gives a qualifying factor for that power, the market-based figure should use it instead. The GHG Protocol asks you to report both figures, location-based and market-based.

The year matters. The same method for 48,50,000 kWh in FY 2024-25 gives 4,850 MWh x 0.710 = 3,443.50 tCO2.

Run the Scope 2 calculator on your own bills.

The CCTS figure is different

CCTS does not use the reporting year's factor. BEE's Detailed Procedure v1.0, s.5(7)(vi), fixes the grid factor of the baseline year for every compliance year. The baseline year is FY 2023-24, so CCTS uses 0.727 in FY 2025-26 and FY 2026-27 alike.

For the same 1,200 MWh all bought from the grid, the CCTS figure is 1,200 x 0.727 = 872.40 tCO2, against 810.00 tCO2 in the BRSR or GHG inventory. If the 300 MWh of open access solar meet the CCTS conditions below, only the other 900 MWh count: 900 x 0.727 = 654.30 tCO2. Never copy one into the other. Our guide to CEA grid emission factors explains the rule, and how to calculate emission intensity shows where Scope 2 sits in the CCTS boundary.

The calculator gives the inventory figures, location-based and market-based. CCTS has its own rule (BEE Detailed Procedure v1.0 s.5(17)): renewable power bought through open access, a dedicated PPA or a green tariff counts as zero, but only with its documents and the plant's undertaking against double counting, and renewable energy certificates bought for the RPO or voluntarily are no claim.

What the figure leaves out

  • Captive power. Electricity from your own coal plant or diesel generator is Scope 1. Price the fuel with the Scope 1 fuel calculator instead, and do not count that power again in Scope 2.
  • Purchased steam and heat. These are Scope 2 too, at the supplier's factor. This calculator covers electricity only.
  • Transmission and distribution losses. These belong to Scope 3 (fuel- and energy-related activities). The emission factor lookup lists the factor CarbonNeeti uses for them.
  • Monthly detail and evidence. The calculator takes a year's total. A report needs each bill, the factor's edition and the fiscal year behind every figure, so your Verifier can trace it.

Where CarbonNeeti fits

CarbonNeeti does this for every plant and every bill, checks each renewable contract against the Quality Criteria, and keeps the evidence for your Verifier. We prepare. You file.

Related reading: Scope 1 vs Scope 2 emissions, and the method behind the Scope 1 fuel calculator.

Share

We prepare. You file. This is general information, not legal advice; check the cited source.

Free for 30 days. No credit card.

Try CarbonNeeti on your own bills.

Found something wrong or out of date in this post?Tell us what we got wrongAll posts